CKTGJ - 110-6716, LITHIUM SULFUR DIOXIDE BATTERY
- MSDS: CKTGJ
- Manufacturer: SAFT AMERICA INC ADVANCED BATTERY SYSTEMS DIV
- Product Name: 110-6716, LITHIUM SULFUR DIOXIDE BATTERY
- National Stock Number: 5845-01-441-9539
Product Identification
Product ID:110-6716, LITHIUM SULFUR DIOXIDE BATTERY
MSDS Date:03/20/1998
FSC:5845
NIIN:01-441-9539
Status Code:A
Kit Part:Y
MSDS Number: CKTGJ
Responsible Party
VALDESE, NC 28690-9643
US
Emergency Phone: 800-424-9300
Info Phone: 828-874-4111/912-245-2806
Cage: 7X634
Contractor
Telephone: 904-985-4631
Cage: 7A529
Ingredients
LITHIUM METAL
CAS: 7439-93-2
RTECS: OJ5540000
SULFUR DIOXIDE
CAS: 7446-09-5
RTECS: WS4550000
OSHA PEL 13 MG/M3;5 PPM
ACGIH TLV: 5.2 MG/M3;2 PPM
ACETONITRILE
CAS: 75-05-8
RTECS: AL7700000
OSHA PEL 70 MG/M3;40 PPM
ACGIH TLV: 67 MG/M3;40 PPM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ACETYLENE BLACK
CAS: 1333-86-4
RTECS: FF5800000
OSHA PEL 3.5 MG/M3
ACGIH TLV: 3.5 MG/M3
Hazards
LD50 LC50 Mixture:NO DATA PROVIDED BY RESPONSIBLE PARTY.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:DEPENDING ON THE CONCENTRATION OF
SULFUR DIOXIDE EXPOSURE, IT ACTS AS AN ASPHYXIANT AND MAY POSSIBLY
CAUSE UNCONSCIOUSNESS WITH NO KNOWN CHRONIC HEALTH EFFECTS.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:SULFUR DIOXIDE-IRRITATION OF NOSE, THROAT,
EYES, AND/OR SKIN-SUFFOCATING ODOR.
Medical Cond Aggravated by Exposure:SULFUR DIOXIDE- ASTHMA AND OTHER
RESPIRATORY DISEASE
First Aid
First Aid:IF CELL VENTS, PERSONNEL SHOULD BE EVACUATED FROM
CONTAMINATED AREAS. ARTIFICIAL RESPIRATION SHOULD BE GIVEN IF
BREATHING STOPS. FLUSH ANY MATERIAL FROM SKIN.
Fire Fighting
Extinguishing Media:USE WATER OR CO2 ON BURNING LITHIUM SULFUR DIOXIDE
CELLS OR BATTERIES. USE A CLASS D FIRE EXTINGUISHING AGENT ONLY ON
A RAW LITHIUM FIRE.
Fire Fighting Procedures:USE SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:BATTERY MAY VENT WHEN SUBJECT TO
EXCESSIVE HEAT EXPOSING CONTENTS.
Accidental Release
Spill Release Procedures:REMOVE PERSONNEL FROM AREA UNTIL FUMES
DISSIPATE. PROVIDE MAXIMUM VENTILATION TO CLEAR OUT HAZARDOUS
GASES.
Neutralizing Agent:NO DATA PROVIDED BY RESPONSIBLE PARTY.
Handling
Handling and Storage Precautions:HERMETICALLY SEALED LISO2 CELLS DO NOT
OUTGAS. HOWEVER, IF EXPOSED TO EXTREME TEMPERATURES OR ROUGH
HANDLING, THEY MAY RELEASE SULFURDIOXIDE GAS IF THE VENT IS
ACTIVATED OR THE BATTERY DAMAGED. (SEE S UPPLEMENTAL).
Other Precautions:DO NOT REMOVE OR BYPASS ELECTRICAL OR THERMAL FUSES.
DO NOT HEAT ABOVE 70C.
Exposure Controls
Eye Protection:SAFETY GLASSES WITH SIDE SHIELDS.
Supplemental Safety and Health
HANDLING/STORAGE: A WELL-VENTILATED STORAGE AREAS SHOULD BE USED TO
PREVENT INADVENTENT CONCENTRATION OF THE GAS IF EXTREMES ARE
ANTICIPATED. IF LARGE QUANTITIES OF BATTERIES ARE STORED, IT MAY
BE AD VISABLE TO INSTALL ALARM DEVICES IN THE STORAGE AREA TO
DETECT SMOKE OR ACCUMULATION OF GASES.
Chemical Properties
HCC:G3
Melt/Freeze Pt:=190.C, 374.F
Spec Gravity:>1
Solubility in Water:NOT SOLUBE IN WATER
Stability
Stability Indicator/Materials to Avoid:YES
HEATING, MECHANICAL ABUSE AND ELECTRICAL ABUSE (SUCH AS RECHARGING,
VOLTAGE REVERSAL AND SHORT CIRCUITING MAY RESULT IN VENTING.
Stability Condition to Avoid:BATTERY CONTAINS HERMETIICALLY SEALED
CELLS AND IS NONREACTIVE PROVIDED THE BATTERY INTEGRITY IS
MAINTAINED AND COIL SEAL REMAINS INTACT
Disposal
Waste Disposal Methods:DISPOSE OF CELL OR BATTERY IN ACCORDANCE WITH
LOCAL, STATE, AND FEDERAL ENVIRONMENTAL REGULATIONS.
Toxicology
Toxicological Information:NO DATA PROVIDED BY RESPONSIBLE PARTY.
Other Information
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ecology
Ecological:NO DATA PROVIDED BY RESPONSIBLE PARTY.
Transport
Transport Information:US DOT PROPER SHIPPING NAME: LITHIUM BATTERIES.
UN HAZARD CLASS: CLASS 9. UN ID NO: UN3090. HAZARD LABEL:
MISCELLANEOUS HAZARD. CONTAINER MARKING: MISCELLANEOUS HAZARD.
PLACARD: MISCELLANEOUS.
Regulatory
SARA Title III Information:NO DATA PROVIDED BY RESPONSIBLE PARTY.
Federal Regulatory Information:NO DATA PROVIDED BY RESPONSIBLE PARTY.
State Regulatory Information:NO DATA PROVIDED BY RESPONSIBLE PARTY.